Despatch MIC1462 Controller Quick Start Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Panel De Control Despatch MIC1462 Controller Quick Start. Despatch MIC1462 Controller Quick Start User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
REV. 8-02
P.N. 211142
MIC 1462 1/4 DIN SETPOINT PROGRAMMER
QUICK START USER MANUAL
Copyright © 2002 by Despatch Industries
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - QUICK START USER MANUAL

REV. 8-02 P.N. 211142 MIC 1462 1/4 DIN SETPOINT PROGRAMMER QUICK START USER MANUAL Copyright © 2002 by Despatch I

Pagina 2 - TABLE OF CONTENTS

8 STEP DESCRIPTION MESSAGE DISPLAY FUNCTION AVAILABLE SETTING 5 Program Lock LockProg Defines whether the operator is permitted to change prog

Pagina 3 - KEYPAD OPERATION

9 Program Parameters (apply as a whole to a specific program) (Program Number = 1 to 8, Segment = Blank) 1. Press the mode key until the message d

Pagina 4

10 STEP DESCRIPTION MESSAGE DISPLAY FUNCTION AVAILABLE SETTING 7 Start Time** Strt-ti Determines the automatic start time for the profile 1:00 -

Pagina 5 - INDICATORS

11 Segment Profile Parameters Table STEP DESCRIPTION MESSAGE DISPLAY FUNCTION AVAILABLE SETTING 1 Final Setpoint Value Final SP Defines the fin

Pagina 6 - DISPLAYS

12 Exiting Profile Set Mode The operator may exit from Profile Set Mode by pressing the MODE key. To return to Base Mode, press the MODE key until

Pagina 7

13 Entering Global Parameters For The Profile Press the mode key until Prof Par is displayed in the Message Display. Press the SCROLL key and Cycl

Pagina 8

14 Running The Profile Press the PROF key until 1 is displayed in the Program Display. Press the Run/HOLd key until 1 is displayed in the Segment

Pagina 9 - MIC 1462 PROFILE PROGRAMMING

TABLE OF CONTENTS POWER UP PROCEDURE... 1 KEYPAD OPERATION.

Pagina 10

1 POWER UP PROCEDURE Verify all electrical connections have been properly made before applying power to the instrument. If the instrument is being

Pagina 11

2 DOWN Key Decrements displayed parameter value/cycles through options. PROF Key Cycles through Program (profile) numbers. RUN/HOLD Key Runs,

Pagina 12

3 INDICATORS Control Status Indicators AT - On when Self-Tune is active; flashes when PreTune is active. ALM - Flashes when any alarm is active.

Pagina 13

4 Mode Indicators SET - On when Profile Set Mode is entered; flashes when viewing parameters in Configuration Mode after entry from Base Mode. PR

Pagina 14 - SAMPLE PROFILE

5 Single Setpoint/Base Mode Control With the Setpoint Programmer in Base Mode (i.e. with the RUN, HLD, SET, and PRG indicators off), the two main d

Pagina 15

6 indicator will go on continuously. When the operator removes the manual Hold (by pressing the RUN/HOLD key again), the HLD indicator will either

Pagina 16

7 MIC 1462 PROFILE PROGRAMMING Programming a profile into the MIC1462 control is broken into three categories: GLOBAL - Those parameters common to

Comentarios a estos manuales

Sin comentarios