Despatch Protocol Plus Controller (Heat/Cool) Manual de usuario

Busca en linea o descarga Manual de usuario para Panel De Control Despatch Protocol Plus Controller (Heat/Cool). Despatch Protocol Plus Controller (Heat/Cool) User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 45
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
PROTOCOL
PROTOCOL PROTOCOL
PROTOCOL
PLUS
PLUSPLUS
PLUS
™ CONTROL
CONTROLCONTROL
CONTROL
HEAT/COOL VERSION
HEAT/COOL VERSIONHEAT/COOL VERSION
HEAT/COOL VERSION
INSTRUCTION MANUAL
INSTRUCTION MANUALINSTRUCTION MANUAL
INSTRUCTION MANUAL
SOFTWARE VERSION 3.1
SOFTWARE VERSION 3.1SOFTWARE VERSION 3.1
SOFTWARE VERSION 3.1
E
-
101
PN 157427
REVISION B
6/2002
Vista de pagina 0
1 2 3 4 5 6 ... 44 45

Indice de contenidos

Pagina 1 - PLUSPLUS

PROTOCOL PROTOCOL PROTOCOL PROTOCOL PLUSPLUSPLUSPLUS ™ CONTROLCONTROLCONTROLCONTROL HEAT/COOL VERSIONHEAT/COOL VERSIONHEAT/COOL VERSIONHEAT/COO

Pagina 2

4 High Limit The control has an integrated high limit function which will disable the heater output when tripped. If the high limit does trip, the r

Pagina 3 - Product Warranty

5 Displays The Protocol Plus control has two displays. A dedicated LED upper display shows the oven temperature. A two-line LCD lower display provid

Pagina 4

6 Outputs The Protocol Plus control has seven different outputs available. • Heating output: The control output is a DC voltage open-collector out

Pagina 5 - TABLE OF CONTENTS

7 Relay (Continued) Use the Relay Card Optional Ay p/n 144562 to add relays to the standard controller. Each relay card contains two relays (maximum

Pagina 6

8 INSTRUCTIONS Start-Up These instructions are provided as a quick reference for operating the Protocol Plus control. If the Profile Mode is to be

Pagina 7 - Theory of Control Operation

9 Operation Manual Mode Press the Select key until Manual is displayed (note you can press the Run key at any time to activate Manual Mode). 1. P

Pagina 8

10 Timer Mode 1. Press the Select key until Timer is displayed (note you can press the Run key at any time to activate Timer Mode). 2. Press the

Pagina 9 - Fast Start Mode

11 Profile Mode 1. Press the Select key until Profile is displayed. “None” may be displayed if a profile has not been selected or no profiles ente

Pagina 10 - Indicators

12 Setup Mode Configuration of the control and programming of the ramp/soak profiles must be done in the Setup Mode. To access Setup Mode, the contr

Pagina 11 - Key Functions

13 Instructions for Setup Mode Pages Program Page Programming of the profiles is provided on the Program Page. Eight profiles are available with up

Pagina 12 - Outputs

Dear Customer, Thank you for choosing Despatch Industries. We appreciate the opportunity to work with you and to meet your heat processing needs

Pagina 13 - Optional Software

14 Menu Item Display Description Ramp Time Seg 1 Pro-1 Seg-1 Ramp Time Ramp time for segment 1 of profile Event 1 Set Value* Pro-1 Seg-1 Ramp E

Pagina 14 - INSTRUCTIONS

15 Profile # There are eight profiles available. Segment# Recipe segments 1 through 8 may be programmed, each with its own set of events, ramp an

Pagina 15 - Operation

16 Sample Profile Programming Table Profile Number____1______ Profile Name__________ Ramp Soak Events Events Seg-ment Time 1 2 3 4 Temp-erature

Pagina 16 - Timer Mode

17 Auto Start Page (optional) If the optional real time clock has been installed, the Auto Start Page can be configured to automatically start Manua

Pagina 17 - Auto Start Mode

18 Menu Item Display Description Range Enable Autostart Auto Start Enable Enable (yes) or disable (no) the Autostart function No, Yes Sunday mod

Pagina 18 - Setup Mode

19 PID Page The PID Page contains parameters which control the response to the setpoint and process variable input. To access the PID Page, enter t

Pagina 19 - Program Page

20 Control Page The Control Page contains various parameters which control miscellaneous functions. To access the Control Page, enter the Setup Mode

Pagina 20

21 Communication Page (optional) The Communication Page contains parameters for the communications feature. To access the Communications Page, enter

Pagina 21

22 Relay Outputs Page (optional) The Relay Outputs Page configures the four alarm/event outputs. Each output has a dedicated indicator light and can

Pagina 22 - Sample Profile

23 Test Page The Test Page contains parameters which allow manual control of the heat control and optional relay outputs and should be used only for

Pagina 23 - Auto Start Page (optional)

Service Worldwide Phone 612-781-5356; Worldwide Fax 612-781-5485; North American Phone 800-473-7373 e-mail [email protected]; www.despatch.com Please

Pagina 24

24 Zone Calibration Page The Zone Calibration Page allows adjustment of the displayed temperature versus the actual temperature measured by the cont

Pagina 25 - PID Page

25 As an example, the control is displaying 400°F with the setpoint being 400°F, but the center of the oven chamber is actually 395°F. This can oc

Pagina 26 - Control Page

26 Sensor Calibration Page The Sensor Calibration Page has parameters which can change the internal calibration of the temperature sensor input sign

Pagina 27

27 19. Connect a calibration instrument with a type J thermocouple output to the control sensor input. 20. Connect a voltage measurement device to

Pagina 28

28 Enable Page The Enable Page controls access to the other Setup Pages. The setpoint minimum and maximum values, and the security passwords are als

Pagina 29 - Test Page

29 Digital Inputs (optional) The Protocol Plus control can be run by external inputs wired to the control from an external source such as a PLC or c

Pagina 30 - Zone Calibration Page

30 Error Messages and Alarms The Alarm Status Hi-limit LED is flashing. This indicates a problem with the thermocouple, or the Hi-limit setpoint ha

Pagina 31

31 Quick Reference and Default Values Program Page Menu Item Display Default Range Setting Ramp Time Seg 1 Pro-1 Seg-1 Ramp Time 00:00 00m00s

Pagina 32 - Sensor Calibration Page

32 Programming Table Profile Number__________ Profile Name__________ Ramp Soak Events Events Seg-ment Time 1 2 3 4 Temp-erature Time 1 2 3 4 1

Pagina 33

33 Autostart Menu Item Display Default Range Setting Enable Autostart Auto Start Enable No No, Yes Sunday mode Auto Start Sun Mode Off Off, Manua

Pagina 34 - Enable Page

Service Worldwide Phone 612-781-5356; Worldwide Fax 612-781-5485; North American Phone 800-473-7373 e-mail [email protected]; www.despatch.com Despatc

Pagina 35 - Digital Inputs (optional)

34 Control Menu Item Display Default Range Setting Cycle Time Control Cycle Time 1 1 to 60 seconds High limit setpoint Control Hi-Lim SP Max HiL

Pagina 36 - Error Messages and Alarms

35 Real Time Clock Menu Item Display Default Range Setting Day of the week Clock Day Mon Sun, Mon, Tue, Wed, Thu, Fri, Sat Time of day Clock HH:M

Pagina 37

36 Test Menu Item Display Default Range Setting Heater output Test HeatOut Off On High limit relay Test HiLimOut Off On Relay 1 output Test Rly

Pagina 38

37 Enable Page Menu Item Display Default Range Setting Profiles Enable Profile 1-8 Yes Yes or No Autostart Enable Auto Start No Yes or No PID E

Pagina 39

38 Technical Specifications UL, cUL listed: UL file E136675 CE compliance to: • EMC Directive 89-366/EEC • European Standard EN55011/1991 • Eur

Pagina 40

39 APPENDIX: Temperature Scale Conversion and Optional MRC5000 Setup Temperature Scale Conversion (C/F) The Protocol Plus controller can be operate

Pagina 41

i TABLE OF CONTENTS TABLE OF CONTENTS ... i INTRODUC

Pagina 43

1 INTRODUCTION The special features of the Protocol PlusTM control include: • PID tuning • Ramp/Soak programming of up to 64 segments • Segment

Pagina 44 - Technical Specifications

2 Protocol Plus Faceplate and Wiring Diagram

Pagina 45 - APPENDIX: Temperature Scale

3 Operating Modes The Protocol Plus control has five modes of operation available: Stopped Mode: All control and relay outputs are off. Stopped Mo

Comentarios a estos manuales